NEW QUESTION # 143
Refer to the exhibit.

An engineer is performing a health check on ACI. Which statement about interface Ethernet 1/11 is true?

  • A. The interface policy is misconfigured.
  • B. "out-of-service" is the default interface status in ACI.
  • C. The interface is working correctly and fully operational, but it is not in use.
  • D. "out-of-service" indicates that no service graph is in use for this interface.

Answer: A


NEW QUESTION # 144
Refer to the exhibit. A client configures an upgrade of its Cisco Nexus switches that are connected to the Cisco ACI controller, such that the switches are upgraded one at a time. After the upgrade is run, it is discovered that both Cisco Nexus switches were upgraded simultaneously. Which two actions ensure that the switches upgrade one at a time? (Choose two.)

  • A. Select the "Graceful Maintenance" checkbox
  • B. Configure the "Do not pause on failure and do not wait on cluster health" Run Mode
  • C. Choose the "Pause upon upgrade failure" Run Mode
  • D. Place each leaf switch in a different upgrade group
  • E. Check the "Ignore Compatibility" checkbox

Answer: A,D


NEW QUESTION # 145
Refer to the exhibit.

The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?

  • A. Reactivate the zoneset.
  • B. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.
  • C. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
  • D. Reconfigure the initiator and the target to be in the same zones.

Answer: D


NEW QUESTION # 146
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.

Answer:

Explanation:


NEW QUESTION # 147
Refer to the exhibit. Server 1 and Server 2 are bare-metal Windows-based servers and can exchange ICMP PING messages. However, both servers fail to ping their default gateway. Which action resolves the problem?

  • A. Assign the NIC to the pin group.
  • B. Disable Fabric Failover.
  • C. Change the MTU value of the server.
  • D. Set the native VLAN ID to 10.

Answer: D


NEW QUESTION # 148
Refer to the exhibit.

A Cisco UCS B-Series Blade Server is configured to boot from a shared storage via an iSCSI network. When a service profile is associated with the blade, the blade fails to attach the LUN. Which action resolves the issue?

  • A. Establish a Layer 2 connection between the blade and the storage
  • B. Implement a Layer 3 connection between the blade and the storage
  • C. Register the blade as an initiator on the storage array
  • D. Place VLAN 0 on the interface that connects to the storage

Answer: D


NEW QUESTION # 149
Refer to the exhibit.

A Postman call to a Cisco APIC fails. The access credentials were confirmed to be configured as expected. Which action resolves the issue?

  • A. Modify the target protocol type to XML
  • B. Change the IP address to a domain name
  • C. Modify the protocol to HTTP
  • D. Change operation type to POST

Answer: D


NEW QUESTION # 150
Drag and drop the commands from the left onto the correct categories on the right.

Answer:

Explanation:


NEW QUESTION # 151
Refer to the exhibit.

The HSRP instance on both switches is showing as active. Which action resolves the issue?

  • A. Configure the HSRP timers to be the same.
  • B. Configure preempt on only one of the switches.
  • C. Allow VLAN 100 between the switches.
  • D. Configure the IP address of N9K-B on the same subnet as N9K-A.

Answer: C


NEW QUESTION # 152
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.

Answer:

Explanation:


NEW QUESTION # 153
A network engineer must connect a Cisco UCS Fabric Interconnect cluster to the Cisco ACI. VMware ESXi hypervisors have been installed on Cisco UCS blades and a VMware VMM domain has been configured. However, virtual machines fail to reach their default gateway in the Cisco ACI Fabric. The engineer investigates the issue and notices that the VMware Distributed Switch (VDS) teaming policy is set to "Route based on IP hash". Which action resolves the issue?

  • A. Configure the vSwitch Policy on a VDS.
  • B. Disable the On-demand EPG resolution immediacy setting in ACI.
  • C. Disable the VMware Network I/O Control on the VDS.
  • D. Configure the vSwitch Policy on the VMM domain.

Answer: D


NEW QUESTION # 154
Refer to the exhibit. An engineer monitors a Cisco UCS server logs and discovers a blade discovery issue. Which procedure resolves the issue?

  • A. 1. Verify the FSM status on the server.
    2. Decommission the impacted server.
    3. Reset the slot where the server is located.
    4. Recommission the server.
  • B. 1. Verify the server power module.
    2. Decommission the faulty module.
    3. Insert a new power module.
    4. Recommission the new module.
  • C. 1. Verify that the power on self-test operation is failed.
    2. Verify that the server firmware is corrupted.
    3. Decommission the server firmware
    4. Recommission the server with new firmware.
  • D. 1. Verify that server platform power is failed
    2. Resolve the platform power issue.
    3. Reboot the server.
    4. Recommission the server.

Answer: A


NEW QUESTION # 155
Refer to the exhibit.

An upgrade operation fails with an error displayed. Which action resolve the issue?

  • A. Allocate extra space on a flash drive to extract a system image
  • B. Use a different system image
  • C. Use a different kickstart image
  • D. Allocate extra space on a flash drive to extract a kickstart image

Answer: B

Explanation:
Kickstart image verification succeeded. System image has failed.


NEW QUESTION # 156
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.

Answer:

Explanation:


NEW QUESTION # 157
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.

Answer:

Explanation:


NEW QUESTION # 158
Drag each item listed on the left to its proper category on the right Not all items will fit the categories.

Answer:

Explanation:


NEW QUESTION # 159
A Cisco UCSB-Series Blade Server is configured to boot a VMwareESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected but the server fails to boot from the SAN. Which action reserves the problem?

  • A. Set the boot LUN to the highest LUN ID in the storage array
  • B. Set the same WWPN pools for vHBA adapters
  • C. Set the same WWNN pools for vHBA adaptor
  • D. Set the boot LUN to the lowest LUN ID in the storage array

Answer: C


NEW QUESTION # 160
An engineer removes a VMM domain from an endpoint group called EPG-1, but the distributed port group fails to be deleted. Which action must be taken to resolve the issue?

  • A. Migrate all virtual machines in the EPG-1 to different port groups.
  • B. Migrate all virtual machines in the EPG-1 to different hypervisors.
  • C. Remove the port group manually.
  • D. Remove the remaining EPGs from the VMM domain.

Answer: D


NEW QUESTION # 161
A network engineer discovers a DNS resolution problem on a device that is using the Cisco Nexus Bash shell.
The device name is app with an IP address of 10.10.10.1. The primary server IP address is 172.16.10.1 and the secondary server IP address is 172.16.10.2. When the abc.com resolution fails, it should attempt to use efg.com. Which settings must be added to resolv.conf file to resolve the issue?

  • A. Option A
  • B. Option B
  • C. Option D
  • D. Option B

Answer: A


NEW QUESTION # 162
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.

Answer:

Explanation:


NEW QUESTION # 163
......


The Cisco 300-615 exam syllabus includes a variety of topics, including troubleshooting data center protocols, troubleshooting data center storage, troubleshooting data center compute platforms, and troubleshooting data center automation and orchestration. 300-615 exam also covers topics related to security, network virtualization, and application-centric infrastructure. 300-615 exam syllabus is regularly updated to ensure that it covers the latest technologies and trends in the data center domain.


Cisco 300-615 exam is a challenging certification test that requires extensive knowledge and practical experience in data center infrastructure troubleshooting. Candidates who pass 300-615 exam demonstrate their ability to resolve complex issues in data center infrastructure and provide effective solutions to improve the overall performance and reliability of the data center environment. Troubleshooting Cisco Data Center Infrastructure certification provides a competitive edge to IT professionals and enables them to advance their careers in data center operations and management.

 

300-615 Study Guide Cover to Cover as Literally: https://www.examdiscuss.com/Cisco/exam/300-615/

Get Unlimited Access to 300-615 Certification Exam Cert Guide: https://drive.google.com/open?id=1aO7yCYnXVDkWK9HBjn3jgoWvbOkuGlNo

0
0
0
10